- Model NO.: DLA-D2-300A
- Cooling Method: Air-cooled
- Selected Voltage: 380V/50HZ
- Noise Level: Low
- Application Machine: Precision Machine Tool
- Condition: New
- Weight(Kg): 4800
- Transport Package: Plastic Film
- Origin: Shanghai, China
- Type: Air-Cooled
- Unit Structure: Integral
- Compressor Number: 1
- Application Fields: Food Processing
- Certification: ISO, CE
- Size(mm): 2600*2320*2300
- Trademark: DARREN
- Specification: SGS, CE, ISO9001
- HS Code: 8418692090
1. Our factory in Shanghai-15000 square meters
2. Festures for air cooled screw chiller
1) Cooling capacity: 180kw~1520kw
2) Cooling conditions: Chilled water inlet temperature is 12 degrees, outlet temperature is 7 degrees Ambient temperature is 35 degrees
3) Input power: 3P-380V-50Hz, Allowable fluctuate voltage: ± 10%, allowable voltage difference in phase: ± 2%.
4) Measuring noise spot: 2m ahead and 1.5m high in front of chiller with average measurement on four dimensions.
5) Semi-closed 5: 6 asymmetric twin-screw compressor from world-renowned brand, trouble-free operation over 100000hours.
6) Eight stages volume control or 0%-100% automatic regulation.
7) Fluoride-resistant high-performance motor from French.
8) Use PLC microcomputer control from Germany Siemens LCD touch screen, both English and Chinese human-machine interface.
9) Wide range of variable chilled water temperature to meet the industrial requirements throughout whole year.
10) Friendly choose to use environmentally R407C or R134A refrigerant.
11) Free step-down triangle stars starter
12. Dual refrigeration circuits to each other back-up
3. Pictures reference for air cooled screw chiller
4. DARREN Team
  Item                                          Type | DLA- | |||||||||||||||||
1802 | 2202 | 2602 | 2902 | 3202 | 3602 | 4002 | 4552 | 5102 | 5652 | 6202 | 6602 | 7002 | 7602 | 8202 | 8402 | |||
Nominal cooling capacity | KW | 180 | 220 | 260 | 290 | 320 | 360 | 400 | 455 | 510 | 565 | 620 | 660 | 700 | 760 | 820 | 840 | |
104Kcal/h | 15.5Â | 18.9Â | 22.4Â | 24.9Â | 27.5Â | 31.0Â | 34.4Â | 39.1Â | 43.8Â | 48.6Â | 53.3Â | 56.7Â | 60.2Â | 65.3Â | 70.5Â | 72.2Â | ||
RT | 51Â | 63Â | 74Â | 82Â | 91Â | 102Â | 114Â | 129Â | 145Â | 161Â | 176Â | 188Â | 199Â | 216Â | 233Â | 239Â | ||
Nominal heating capacity | KW | 200 | 245 | 290 | 325 | 360 | 405 | 450 | 510 | 570 | 635 | 700 | 745 | 790 | 855 | 920 | 944 | |
104Kcal/h | 17.2Â | 21.1Â | 24.9Â | 27.9Â | 31.0Â | 34.8Â | 38.7Â | 43.8Â | 49.0Â | 54.6Â | 60.2Â | 64.1Â | 67.9Â | 73.5Â | 79.1Â | 81.2Â | ||
RT | 57Â | 70Â | 82Â | 92Â | 102Â | 115Â | 128Â | 145Â | 162Â | 181Â | 199Â | 212Â | 225Â | 243Â | 262Â | 268Â | ||
 Run control | Use PLC microcomputer control | |||||||||||||||||
Power Supply | 380V/3N/50Hz | |||||||||||||||||
Machine power | kW | 65.3 | 73.4 | 89.5 | 94.5 | 105.7 | 114.7 | 126.7 | 139.7 | 152.5 | 172.6 | 192.5 | 205.9 | 219.2 | 238.5 | 257.8 | 262.5 | |
Machine operating current | A | 114.3 | 128.5 | 156.6 | 165.4 | 185 | 200.8 | 221.7 | 244.5 | 266.9 | 302 | 336.9 | 360.3 | 383.6 | 417.4 | 451.2 | 459.6 | |
Compressor |
Type | Semi-closed 5:6 asymmetric twin-screw compressor | ||||||||||||||||
Startup type | YStart | |||||||||||||||||
Energy regulation | 0-12.5%-25%-37.5%-50%-62.5%-75%-87.5%-100% or automatic regulation | |||||||||||||||||
Refrigeration power | kW | 55 | 67.1 | 79.2 | 87.3 | 95.4 | 105.9 | 116.4 | 129.3 | 142.2 | 162.2 | 182.2 | 190.4 | 198.6 | 217.9 | 237.2 | 241.9 | |
Refrigeration current | A | 96.3 | 117.4 | 138.6 | 185.4 | 167 | 226.3 | 203.7 | 283.8 | 248.9 | 333.2 | 318.9 | 381.4 | 347.6 | 423.6 | 415.1 | 461 | |
Heating power | kW | 53.6 | 65.4 | 77.2 | 85.1 | 93 | 103.2 | 113.4 | 126 | 138.6 | 158.1 | 177.6 | 185.6 | 193.6 | 212.4 | 231.2 | 235.8 | |
Heating current | A | 93.8 | 114.5 | 135.1 | 149 | 162.8 | 180.6 | 198.5 | 220.5 | 242.6 | 276.7 | 310.8 | 324.8 | 338.8 | 371.7 | 404.6 | 412.3 | |
Evaporator | Type | Pipe dry high efficiency heat exchanger | ||||||||||||||||
Flow | m3/h | 30.9Â | 37.7Â | 44.6Â | 49.7Â | 54.9Â | 61.7Â | 68.6Â | 78.0Â | 87.4Â | 96.9Â | 106.3Â | 113.1Â | 120.0Â | 130.3Â | 140.6Â | 144.0Â | |
Interface size | DN | 80 | 80 | 100 | 100 | 100 | 100 | 125 | 125 | 125 | 150 | 150 | 150 | 150 | 150 | 200 | 200 | |
Water pressure drop | kPa | 46 | 46 | 47 | 48 | 49 | 50 | 51 | 52 | 52 | 52 | 52 | 54 | 54 | 56 | 57 | 57 | |
Condenser | Type |  Imported efficiency copper pipe and aluminum foil wing heat exchanger | ||||||||||||||||
Air flow | m3/h | 69940 | 85446 | 100952 | 112292 | 123631 | 138661 | 153690 | 173899 | 194107 | 216429 | 238750 | 253095 | 267440 | 291042 | 314643 | 321994 | |
Condenser fan | Quantity | SET | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 8 | 8 | 12 | 12 | 12 | 12 | 12 | 12 |
Stand-alone power | kW | 0.85 | 0.85 | 1.32 | 1.32 | 1.6 | 1.6 | 2.2 | 2.2 | 2.2 | 2.2 | 1.32 | 1.32 | 1.6 | 1.6 | 1.6 | 2.2 | |
Refrigerant |
Type | R22 | ||||||||||||||||
Refrigerant volume | kg | 46 | 67 | 67 | 74 | 82 | 95 | 102 | 115 | 131 | 146 | 159 | 165 | 179 | 194 | 210 | 215 | |
Overall size | Length | mm | 3200 | 3200 | 3200 | 3400 | 3400 | 4000 | 4000 | 4400 | 4400 | 6400 | 6400 | 6400 | 6400 | 6700 | 6700 | 7100 |
Width | mm | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | |
Height | mm | 2300 | 2300 | 2300 | 2300 | 2300 | 2300 | 2300 | 2300 | 2300 | 2300 | 2560 | 2560 | 2560 | 2560 | 2560 | 2560 | |
Noise | dB(A) | 64 | 64 | 64 | 64 | 64 | 64 | 67 | 67 | 68 | 68 | 68 | 68 | 68 | 68 | 69 | 69 | |
Machine weight | kg | 3200 | 3330 | 3330 | 3750 | 3850 | 4200 | 4400 | 4600 | 4800 | 4950 | 5200 | 5450 | 5750 | 5840 | 5900 | 6150 | |
Operating weight | kg | 3500 | 3700 | 3700 | 4100 | 4200 | 4500 | 4800 | 4900 | 5300 | 5500 | 5700 | 5950 | 6300 | 6400 | 6500 | 6850 |
There are some protective device inside the belt conveyor to prevent accidents and ensure the safety when conveying materials. Protections of belt conveyor consist of belt sway protection, belt-broken protection, sliding protection and emergency stop pull switch. Belt sway, belt-broken and sliding protections are course switch with simple structure and low cost, the working principle is that the machine would stop when belt touched switch.