Pipeline centrifugal pump installation skills

    Pipeline centrifugal pumps (also known as ISG vertical centrifugal pumps, ISW horizontal centrifugal pumps, and some single-stage XBD fire pumps are also centrifugal pumps of this type, and they are installed in almost the same way) are widely used in life and Correct installation is the key to long-term use, the correct installation of pipeline centrifugal pump can not only increase the service life of the pump, at the same time can better meet the requirements!
  
Pipeline centrifugal pump installation technology key lies in determining the pump installation height (ie suction). This height refers to the vertical distance from the water surface of the water source to the center line of the pump impeller. It can not be confused with the allowable vacuum height. The allowable vacuum height indicated on the pump manual or nameplate means the vacuum value on the water inlet section of the water pump, Is measured at 1 standard atmospheric pressure, the water temperature of 20 degrees Celsius, the test and measured. It does not consider the condition of the flow of water after the water pipe is supplied. The pump installation height should be allowed to suck vacuum height deducted after the loss of suction pipe head, the remaining part of the value, it is necessary to overcome the actual terrain water absorption height. Pump installation height can not exceed the calculated value, otherwise, the pump will not pump water.
  
Affect the calculated value is the size of the suction pipe lift loss lift, it is appropriate to use the shortest pipe layout, and try to install less elbow and other accessories, but also consider appropriate with larger diameter pipes to reduce the flow rate within the pipe.
  
It should be noted that the pipelines centrifugal pump installation site elevations and water temperature is different from the test conditions, such as the local elevation of 300 meters above or pumping water temperature exceeds 20 degrees Celsius, the calculated value to be amended. Ie atmospheric pressure at different elevations and saturated vapor pressure above 20 degrees Celsius. However, when the water temperature is below 20 degrees Celsius, the saturated steam pressure is negligible.
  
From the pipeline installation technology, the suction pipe requires strict sealing, can not leak, leakage, otherwise it will undermine the pump inlet vacuum, so that the water pump to reduce the amount of water is not even pumping in serious cases. Therefore, we should conscientiously do the work of the interface of the pipeline to ensure the construction quality of pipeline connection.

EVA Double Colors Sheet

EVA Double Colors Sheet is less one production process, which is cutting the grooves than the EVA Faux Teak Sheet. This kind of marine sheet is for customers who own a CNC machine to cut the customized pattern based on what they need.

EVA Double Colors Sheet

Through a CNC machine, you can make something beautiful more than a straight grooves. The CNC machine can help you to route a pattern, a name, a logo or whatever you like. Once it is done, then a simple peel and stick, the cut sheet can be applied on the boat decking without any more cutting.

EVA Double Colors Sheet

Also we are flexible on the colors combination. It can be any color in the bottom, and it can be any color on the top. We intend to provide the best customization for different requirements from different customers.

The standard thickness would be 6mm, but we can also offer a thicker material. For example, to make a customized helm station pad, the thickness should be at lease 13mm or even to 20mm, and this is what we can do for a better products service.

Eva Double Colors Sheet,Eva Marine Sheet,Eva Plastic Foam Sheet,Environmental Eva Foam Sheets,Double Color Eva Foam Sheet ,Double Colors Sheet

Huizhou City Melors Plastic Products Co., Limited , https://www.foamexpert.net